NCC 2025 Compliant
Patent Approved

Paton VentilatedRoof and Wall Battens

Purpose-engineered roof and wall battens delivering NCC 2025-compliant ventilation, superior strength, and exceptional durability.

25,000+

mm² Airflow/m

55+

Years Experience

100%

Australian Made

Pre-Order Now — Battens are made to order. Order ahead to ensure timely delivery.

Coming Soon — Ventilated Battens will be available in BlueScope Steel

See It In Action

Fascia and Ridge Install Demonstration

Player not loading? Watch on YouTube

Coming Soon

Available in 6 metre lengths

We're extending the range with 6 m ventilated battens, giving installers longer continuous runs with fewer joints and quicker set-out on large roof and wall areas.

Register your interest

6 metre lengths

Continuous runs in one piece, no repeated short joins.

Fewer joins

Less cutting, less waste and a cleaner finished line.

Faster install

Fewer lifts and fixings across long roof and wall runs.

NCC 2025 Requirements

Roof Ventilation Requirements by Pitch

Minimum ventilation area required for roof spaces, based on roof pitch.

Roof PitchMinimum Ventilation Required
< 10°25,000 mm²/m provided at each of two opposing ends
≥ 10° and < 15°25,000 mm²/m provided at the eaves and 5,000 mm²/m at high level
≥ 15° and < 75°7,000 mm²/m provided at the eaves and 5,000 mm²/m at high level, plus an additional 18,000 mm²/m at the eaves if the roof has a cathedral ceiling

Paton Ventilated Battens Cover All Roof Pitches

Delivering 25,000 mm² per linear metre, our battens meet the minimum ventilation requirement at every pitch — no guesswork, just a compliant batten every time.

The True Cost of Roof Ventilation

A simple comparison of common roof ventilation batten systems.

Example Scenario: 100m of Battens on a Standard Pitched Roof

ComparisonPaton Steel Ventilated BattensTimber Cavity BattensTraditional Timber Counter Battens
Material cost / m²$11.50$21.40$11.00
Install labour costLowLow–Moderate*Higher*
Cutting & assemblyMinimalModerateAdditional blocking and fixing
Ventilation25,000 mm²/m5,000 mm²/mDesign dependent
Roof pitchAll roof pitches (0–75°)Ridge ventilation above 10°Design dependent
Fire ratingUp to BAL-FZNot ratedNot rated
Additional componentsDependent on ABCB requirementsDependent on ABCB requirementsDependent on ABCB requirements
Total installed cost / m²$18.90$29.80$29.95

*Indicative installation complexity only. Compare equivalent roof designs and compliant installations.

Less cutting. Less fixing. Less labour.

One integrated steel batten designed to provide structural support and continuous roof ventilation.

Download Cost Comparison (PDF)
Compliance Ready

NCC 2025 Condensation Management

For roof condensation management under NCC 2025, the minimum clear ventilation gap is 18 mm, where the roof ventilation provisions apply in climate zones 6–8.

Insulation not parallel to the roof: maintain at least 18 mm between the ceiling insulation and the underside of the roof, including any roof membrane or roof-level insulation.
Insulation parallel to the roof: maintain a continuous ventilation path at least 18 mm deep between the low-level and high-level vents.

Important: Traditional solid roll-formed galvanised steel battens do not meet the new NCC requirements.

Engineering Certification

This product meets the requirements of AS/NZS 4600 for spans up to 1200mm

How Paton Ventilated Batten works
NCC 2025 Ready
Why Choose Us

Engineered for Performance

Our Ventilated Battens provide a smarter, safer, and more efficient approach to roof ventilation and durability.

Optimised Ventilation

Patented design maximises airflow with 25,000mm² ventilation per linear metre, meeting NCC 2025 requirements.

Condensation Control

Triangular openings (34mm × 75mm) promote high airflow, reducing humidity and preventing mould growth.

Superior Strength

Upgraded material gauge and triangulated design deliver excellent compressive strength and wind load performance.

Thermal Performance

Improved ventilation contributes to better energy efficiency and enhanced thermal and acoustic performance.

Modern Compatibility

Designed for modern roof and wall spacing with superior fastener engagement.

Easy Installation

Battens nest for convenient transport and storage. Delivered in strapped bundles of 10 for easy handling.

Our Products

Two Profiles Available

Choose the right batten for your roofing or wall application

VB350 Wall Batten
VB350

VB350 Wall Batten

Bundle of 10

35mm
3m Length

35mm high ventilated batten designed specifically for walls.

$297.00

+GST per bundle

VB500 Roofing Batten
VB500

VB500 Roofing Batten

Bundle of 10

50mm
3m Length

50mm high ventilated batten designed specifically for roofs.

$334.60

+GST per bundle

Paton Industries
Why Choose Us

Paton Industries

With over 55 years of experience, Paton Industries is a trusted name in Australian manufacturing. Known for our commitment to design excellence, durability and performance in livestock equipment, we are now extending this expertise into the construction industry.

Our ventilated battens are designed and manufactured right here in Victoria, Australia, ensuring the highest quality standards and supporting local industry.

55+

Years Experience

VIC

Australian Made

100%

Quality Assured

Ready to Get Started?

Contact us today for a quote on NCC 2025-compliant ventilated battens. Our team is ready to help with your roofing project.